Especially with reciprocationg positive-displacement pumps, interactions with connected pipelines and system parts must be taken into consideration. We check your installation using pulsation studies and ensure that the entire system later operates reliably, safely and without downtimes already in the planning phase.
We inspect your installation, considering the complexities of the system, the kinematics and number of cylinders of the pump, as well as the stroke frequency range and the properties of the fluids. With many years of experience, we can assess the fluid professionally.
With the LEWA installation inspection you already ensure during the planning stage that the entire system (pump with pipeline) will work reliably. Reduced investment costs based on optimal dimensioning and positioning of the components and long service life of the entire system are the results.
We discuss the basic requirements of an reciprocationg pump with you. Efficiency is all about the question of which components are required and how to arrange them. In addition, a detailed assessment of the liquid to be dosed is required for a professional assessment of the overall system.
We perform an analytical study with our software PumpDesign. This provides information on:
We are the only pump manufacturer worldwide that also performs numeric simulations and test API 674/675 criteria. This will give you exact evidence, without any deouts to external institutions, on dynamic processes in complex pipeline systems (e.g., parallel operation of pumps) and pressure amplitudes.
These analyses are used for optimization of pulsation damping and pipeline dimensioning. In this way we prevent typical problems by exact calculation, such as cavitation and vibrations as well as fatigue damage to pipelines and components. The results of the study are summarized in a corresponding documentation.
We offer this service as the world's only pump manufacturer. Without time-consuming detours via external institutions you get accurate information. In this case, the piping system is tested according to the following criteria:
Considering the complexity of the system, the kinematics of the cylinders and the control range of the pump as well as the properties of the fluid we verify your installation.